Beacon command, setting of beacon parameters (tracker mode)
beacon
Beacon setup
Beacon <param> <value>
SmartBeacon
LowSpeed
HighSpeed
Distance
StopSpeed
MinTime
MaxTime
FixTime
SlowTime
TurnTime
TurnAngle
TxBatStatus
TxTempStatus
TxBatPrevent
BatVolt
TxStatusFrq
TxQrvFreq
TxQrvSplit
TxQrvTone
QrvFreq
QrvFreqNarrow
QrvFreqSplit
QrvFreqTone
Conf
Init
MicEmsg
Save
beacon conf
Beacon Conf:
Smart Beacon configuration : S-1
0: Fixed time interval.
1: Distance (accumulated).
2: Dynamic time by speed.
3: Distance (vector).
Fixed Time interval S-0 : 120 Seconds
Distance interval S-1+3 : 800 meters
Low Speed limit S-2 : 4 km/H
High Speed limit S-2 : 70 km/H
Stopped Speed limit S-1+2+3: 4 km/H
Maximum Time interval S-1+2+3: 120 Seconds
Minimum Time interval S-1+2+3: 60 Seconds
Slow Time interval S-1+2+3: 1200 Seconds
Turn Angle trigger level S-1+2+3: 15 Degrees
Turn Time S-1+2+3: 2 Seconds
Tx Battery status all : 0
Tx Temperature status all : 0
Tx disable Battery low all : 0
Voltage low limit all : 0 mV
Tx Status interval 0-10 all : 1/6
Tx QRV frequency all : 0
Tx QRV frequency Split all : 0
Tx QRV frequency Tone all : 0
QRV frequency all :
QRV frequency Narrow all : 0
QRV freq split -9900/+9900 all : 0000 kHz
QRV freq tone 000/251 all : 0
MicE message 0-7 all : Off Duty
Execute 'beacon save' to store in flash.